Please be aware this is pre order
The products will be shipped to you once they become available
Power adapter input:100-240Vac,50/60Hz,2.5A
Main unit input:15V 6.0A MAX
Wavelength and power:
a) 976 ± 20 nm :
0.3W-7W(CW), Peak Power 16W;
chopped 1Hz to 20KHz
chopped mode:5us – 0.9S
b) 650 ± 20 nm :
25mW-200mW(CW)
Laser classification:
a) 976 nm: Class 4;
b) 650 nm: Class 2;
Aiming beam: 650 ± 20 nm /Pmax<5mW (class 1)
Divergence:12.7° (According to IEC 60825-1: 2014)
Rechargeable battery:
11.1V/2600mAh x2 (57.7Wh)
Time consumption for charging: about 4h (5 hours for first charging)
Size: 22 cm x 20cm x 23cm
Weight: 1.5kg
Power adapter input:100-240Vac,50/60Hz,2.5A
Main unit input:15V 6.0A MAX
Wavelength and power:
a)976± 20nm :
0.2W-4W(CW), Peak Power 7W
chopped 1Hz to 20KHz
chopped mode:5us – 0.9S
b)650± 20nm :
25mW-200mW(CW)
c)450± 20nm:
0.2W-3W(CW), Peak Power 4W
chopped 1Hz to 20KHz
chopped mode:5us – 0.9S
Laser classification:
a) 976 nm: Class 4;
b) 650 nm: Class 2;
c) 450 nm: Class 4;
Aiming beam: 650 ± 20 nm / Pmax<5mW (class 1 )
Divergence:12.7° 3
(According to IEC 60825-1: 2014)
Rechargeable battery:
11.1V/2600mAh x2 (57.7Wh)
Time consumption for charging: about 4h (5 hours for first charging)
Diverging half angle: 0.22 mad/ 12.6 °
size: 22 cm x 20cm x 23cm
Weight: 1.5kg
1. Laser x 1
2. Handpiece shell x 1
3. MF2-14 [single-use only tips] x 2
4. MF2-20 [single-use only tip] x 1
5. MF3-4 [single-use only tips] x 3
6. MF3-9 [single-use only tips] x 3
7. MF4-4 [single-use only tips] x 3
8. MF4-9 [single-use only tips] x 3
9. DT15-Tip [Reusable tip] x 1
10. DT20-Tip [Reusable tip] x 1
11. DT30-Tip [Reusable tip] x 1
12. BT8-Tip [Reusable tip] x 1
13. Whitening-Tip [Reusable tip] x 1
14. Bending Tool x 1
15. Articulating Paper x 1
16. Cutting Pen x 1
17. Remote Control Interlock x 1
18. Goggles x 3
19. Adapter x 1
20. Instruction Manual x 1
Main Unit: 2 Years / Handpiece: 1 Year / Accessory Parts: 6 Months / Consumables: No Warranty
Range of warranty:
Within the warranty period of validity, we are responsible for any troubles caused by quality problems or products technique and structure.
The following are beyond our warranty:
The damage caused by disobeying the operation instruction or lack of the needed conditions.
The damage caused by unsuitable operation or disassembly without authorization.
The damage on product that caused by users’ unexpected drop or impact to product.
The damage caused by unadvisable transportation or preservation.
There isn’t the seal of distributor, or the warranty card isn’t filled in completed.
El D-Laser Blue se puede utilizar en los campos de cirugía de tejidos blandos dentales, enfermedades endodónticas, enfermedades periodontales, tratamiento del dolor, terapia con láser blando y otras enfermedades bucales vaporizando, carbonizando y solidificando el tejido mediante láser.
Efecto notable del tratamiento:
Básicamente no hay sangrado durante la operación, lo que minimiza al máximo la hinchazón postoperatoria, reduce el dolor de los pacientes y acelera la recuperación.
1. La innovadora tecnología láser azul de 450 nm es ideal para el corte, la ablación, la coagulación y la incisión/escisión de tejidos blandos. A 450 nm, la constante de absorción de la hemoglobina es de dos órdenes de magnitud para los láseres comunes (por ejemplo, 980 m/810 m), lo que hace que solo se necesite una potencia láser muy baja para completar el tratamiento y el daño térmico durante el tratamiento sea extremadamente bajo.
2. 976nm es un láser dental infrarrojo tradicional. Debido a su penetración profunda en los tejidos, se utiliza ampliamente para la reducción de bacterias en enfermedades periodontales y endodónticas. Al mismo tiempo, esta longitud de onda también es adecuada para el tratamiento con láser de alta potencia (HPLT) y la reducción del dolor en la ATM.
3. El láser de 650 nm se utiliza para efectos de terapia láser de baja intensidad (LLLT). También se lo conoce como efecto de fotobiomodulación (PBM). Contribuirá a la cicatrización de heridas y a la bioestimulación de la cirugía dental.
Here are some videos for your viewing!
General Usage and Features
Q: How is the D-Laser Blue different from regular lasers?
A: Compared to typical dental lasers, the D-Laser Blue offers:
Q: Can the D-Laser Blue be used for different oral surgeries?
A: Yes, it is effective for various procedures such as abscess treatment, frenectomy, pulp disease therapy, and general soft tissue surgeries.
Safety and Contraindications
Q: Are there any patients who shouldn’t use this laser?
A: Yes, the laser should not be used on:
Q: What safety measures are required during use?
A: All personnel (including the doctor, assistants, and patient) must wear laser goggles provided by the manufacturer to protect their eyes. Unauthorized goggles should not be used.
Q: What should be done if the aiming beam is not visible?
A: Check the beam setting and increase it if necessary. If the problem persists, replace the fiber optic tip or contact the dealer.
Handling and Maintenance
Q: How should the fiber tips be prepared before surgery?
A: Before use, the fiber tip must be cut and activated. Gently traverse the fiber with the cutting pen to remove any debris or damaged parts. Activate the tip by running it over articulating paper with the laser set at 976 nm and 3W continuous power.
Q: How should the laser be cleaned and maintained?
A: Ensure the device is clean before and after each use. Handle the handpiece with care to avoid scratches, and avoid pulling or bending the tail wire to prevent damage.
Q: What precautions should be followed for safe storage?
A: Store the D-Laser Blue away from heat sources, magnetic fields, precision instruments, and unstable voltage environments. Avoid using it near flammable anesthetic mixtures.
Charging and Battery Information
Q: How does the D-Laser Blue indicate its battery status?
A:
Q: Can the device operate while being charged?A: Yes, the D-Laser Blue can be used while connected to the original power adapter. However, it is primarily designed to function as a battery-powered, portable unit.
Procedural FAQs
Q: How is a frenectomy performed using the D-Laser Blue?
A:
Q: How does the D-Laser Blue treat abscesses?
A:
Troubleshooting
Q: What should I do if the laser beam is not working properly?
A: Try increasing the power. If the laser beam still doesn't work at 3W or higher, replace the fiber optic tip. If the issue persists, contact the dealer for assistance.
Q: What if the foot switch doesn’t control the laser?
A: Ensure the foot switch is fully charged and properly paired with the device. If the problem continues, seek technical support from the dealer.
Laser Presets and Protocols – FAQs
1. What are the laser settings for epulis removal?
2. What is the protocol for fibroma removal using the laser?
3. How is gingivectomy performed with this laser?
4. What are the settings and steps for gingivoplasty?
5. How do I perform a laser incision for a biopsy?
6. What are the steps for operculectomy using the laser?
Cleaning, Disinfection, and Sterilization – FAQs
1. Which tips are reusable, and which are single-use only?
2. What are the sterilization limitations?
3. How many times can items be sterilized?
4. What steps are required for initial processing?
5. How should used devices be transported?
6. What are the recommended cleaning procedures?
7. What is the recommended disinfection procedure?
8. How should the products be dried?
9. How should products be inspected and maintained?
10. What packaging materials should be used for sterilization?
11. What is the correct sterilization method?
12. How should products be stored?
13. What precautions should be taken during transportation?
14. How should the main unit and accessories be cleaned?
15. Are there any cleaning warnings or special instructions?
Handpiece Optical Components: Protect from water exposure.
Es proporcionar equipos/suministros de alta calidad para todos los profesionales dentales.
!