Compatible With SATELEC® / ACTEON® / DTE®
Main unit input: ~100V-240V 50Hz/60Hz 0.4A Max
Output primary tip vibration excursion: ≤90μm
Output half-excursion force:<2N
Output tip vibration frequency: 28kHz±3kHz
Output power: 3W to 20W
Main unit fuse: T0.5AL 250V
Water pressure: 0.01MPa to 0.5MPa
Weight of main unit: 1.8kg
1. Main Unit x1
2. Detachable Handpiece x1
3. Power Cord x1
4. Foot Switch x1
5. Torque Wrench x1
6. 5Endo Wrench x1
7. Water Pipe x1
8. .Quick-Connector for Water x1
9. 700ml Water Bottle x1
10. Waterproof O-Ring
11. Bottle Sealed Ring
12. LED Lamp x1
13. LED Lamp Replacement Instructions x1
14. Instruction Manual x1
15. Quality Certification x1
16. Warranty Card x1
17. Packing List x1
Included Ultrasonic Tips:
18. GD5 x1
19. ED12D x1
20. PD7 x1
21. PD12 x1
22. ED3D x1
23. ED6 x1
24. ED15 x1
25. ED60 x2
Period validity:
Main Unit: 1 Year / Handpiece: 1 Year / Accessory Parts: 6 Months / Consumables: No Warranty
Range of warranty:
Within the warranty period of validity, we are responsible for any troubles caused by quality problems or products technique and structure.
The following are beyond our warranty:
Recommended for treating simple cases and gross supragingival
scaling.
Here are some videos for your viewing. Enjoy!
1. How often should the scaling tips be replaced?
• Scaling tips can undergo up to 300 sterilization cycles before they need to be replaced. Monitor for signs of reduced vibration or buzzing, as these may indicate a damaged tip that needs replacement.
2. How do I install the scaling tip on the Woodpecker / DTE Ultrasonic Scaler?
• Ensure the scaling tip, wrench, and handpiece have been sterilized before installation. Use the provided torque wrench to securely tighten the scaling tip onto the handpiece.
3. How do I adjust the water flow for the scaling tips?
• To adjust the water flow, use the water control knob. It’s best to start with the knob set to maximum, then adjust based on cooling and cleaning needs.
4. Why is my scaling tip’s vibration weak?
• A weak vibration can result from a loose scaling tip or a damaged tip. Tighten the scaling tip with the torque wrench. If the tip still vibrates weakly, it may need to be replaced.
5. How do I avoid damaging the scaling tip or teeth during use?
• Avoid pressing the tip too hard against the teeth and do not position the tip vertically on the tooth surface. Use a light, to-and-fro motion with minimal pressure to ensure effective and safe scaling.
6. What cleaning methods are recommended for the scaling tips?
• Cleaning should occur within 24 hours post-operation and can be done manually or with an automated cleaner. For automated cleaning, ensure it adheres to EN ISO 15883 standards, with proper temperature control and cleaning agents like distilled or deionized water.
7. How should I sterilize the scaling tips?
• Sterilization should follow a thorough cleaning and disinfection process. Tips can withstand up to 300 sterilization cycles at a maximum temperature of 138°C.