Power Input: AC 100-240V 50Hz/60Hz
Host Size: 155mm×167mm×227mm
Size of fuse: 5.2 mm×20mm
Speed (r/min): 300 ~ 42000
Torque range (20:1): 5N∙cm- 80N∙cm
Max water volume: 135ml/min
Motor size: φ23. 4mmxL91mm
Motor weight: 140g
Motor Model: SPM58L, SPM58NL, SPM58LS, SPM58, SPM45L,
SPM45NL, SMP60L, SMP60NL
Input Power: 180VA
Software Version: V1
Ambient Temperature Range: +5 ~ 40°C
Relative Humidity Range: 30% ~ 75%
Atmospheric Pressure Range: 70kPa ~ 106kPa
Handpiece Gear Ratios Output speed (r/min)
16: 1 20 ~ 2500
20: 1 15 ~ 2000
27: 1 10 ~ 1500
1: 1 300 ~ 42000
1: 2 600 ~ 84000
1: 2.7 810 ~ 113400
1: 3 900 ~ 126000
1: 4.2 1260 ~ 176400
1: 5 1500 ~ 210000
Specifications of multi-function pedals:
Model: MF4;
Tail line length: 2.8m;
1. Main unit x 1
2. Power cord x 1
3. Handpiece holder x 1
4. Disposable water pipe x 4
5. Infusion bottle holder x 1
6. Disinfection plug x 2
7. Pipe clamp x 10
8. O-ring (Motor) x 4
9. Foot pedal x 1
10. Motor handpiece x 1
11. Contra-angle kit x 1
13. Spare fuse x 2
14. Instruction manual x 1
15. Qualified certificate 1
16. Instruction Card x 1
Period validity:
Main Unit: 1 Year / Handpiece: 1 Year / Accessory Parts: 6 Months / Consumables: No Warranty
Range of warranty:
Within the warranty period of validity, we are responsible for any troubles caused by quality problems or products technique and
structure.
The following are beyond our warranty:
- The damage caused by disobeying the operation instruction or lack of the needed conditions.
- The damage caused by unsuitable operation or disassembly without authorization.
- The damage on product that caused by users’ unexpected drop or impact to product.
- The damage caused by unadvisable transportation or preservation.
- There isn’t the seal of distributor, or the warranty card isn’t filled in completed.
Revolutionizing Implant Surgery with Advanced Technology
The Woodpecker Implant Air Implant Motor, available through SoniDent, is a state-of-the-art dental unit designed to elevate the precision, efficiency, and reliability of your implant procedures. Completely redesigned with advanced features, it’s the ideal companion for modern dental professionals.
Key Features:
1. Continuous and Reliable Torque Output
Ensure unparalleled precision with real-time torque display that maintains the preset value throughout the procedure. Unlike traditional implant motors that may auto-stop or reduce torque, the Implant Air delivers consistent and reliable output, giving practitioners confidence in achieving the desired torque for optimal implant stability.
2. Automatic Torque Calibration for Accuracy
Eliminate the need for manual calibration with the Implant Air’s Torque Startup Automatic Calibration (TSAC) feature. Every time the unit powers on, it self-calibrates to ensure absolute accuracy, simplifying the workflow and enhancing operational reliability.
3. Compact Design with User-Friendly Interface
The Implant Air’s space-saving design is perfect for compact operatories. Its streamlined body measures only 6.1 inches (L) x 6.5 inches (W) x 8.9 inches (H), minimizing clutter while providing full functionality. The 5-inch color LCD touchscreen is intuitive, featuring 5 pre-set surgical programs that automatically save parameters after each operation.
4. Ultra-Quiet Peristaltic Pump
Equipped with a waterproof design, the Implant Air prevents circuit board burnout and ensures safe operation. Its peristaltic pump is user-friendly, supports disposable water sources, and operates at a maximum water volume of 135ml/min, delivering consistent irrigation with minimal noise.
5. Advanced Multi-Function Foot Pedal
Stay focused on your procedure with hands-free control. The versatile foot pedal allows you to:
6. Swiss Motor and German Handpiece Technology
Experience unmatched power and durability with Implant Air’s Swiss motor and German bearings in the 20:1 LED contra angle. This combination ensures smooth, precise torque delivery and long-lasting performance.
7. Compatibility and Versatility
The Implant Air is designed to meet the diverse needs of dental professionals, compatible with all E-type contra-angle handpieces and offering a wide range of speed ratios: 16:1, 20:1, 27:1, 1:1, 1:2, 1:2.7, 1:3, 1:4.2, and 1:5.
8. Ergonomically Designed for Comfort
The lightweight and ergonomic design of the contra-angle handpiece minimizes fatigue, even during long procedures, ensuring optimal comfort for the practitioner.
9. Enhanced Operational Monitoring
The user interface includes a peak value display for real-time recording of peak torque output, helping practitioners judge the implant's initial stability with precision.
Here are some videos for your viewing. Enjoy!
General Usage
Q: How do I set up the Woodpecker Implant Air Implant Motor for use?
A: Follow these steps:
Q: Can I use any handpiece with the Implant Air?
A: The device is compatible with a variety of E-type contra-angle handpieces and speed ratios, including 16:1, 20:1, 27:1, and more. For accurate torque monitoring, it’s recommended to use matching handpieces as specified in the manual.
Q: What does the Peak Torque Display show?
A: The Peak Torque Display records the highest resistance encountered during implant placement, helping assess the implant's stability.
Cleaning and Maintenance
Q: How should I clean the Woodpecker Implant Air?
A:
Q: Can I sterilize all parts of the device?
A: Only the following components are sterilizable:
Q: How often should I clean the motor handpiece?
A: Clean and disinfect the motor handpiece immediately after each use and ensure it is thoroughly dried before storage.
Disinfection
Q: What disinfectants are safe to use on the device?
A: Use aldehyde-free surface disinfectants certified by officially recognized institutes. Avoid chlorine-based disinfectants.
Q: Can I disinfect the main unit and foot controller?
A: Yes, use a soft cloth dampened with 75% alcohol to wipe their surfaces. Do not spray disinfectants directly onto the device.
Troubleshooting
Q: What should I do if I see an error code on the display?
A: Refer to the Error Code section in the manual. Common issues include:
Q: The torque output seems incorrect. What could be the issue?
A: Ensure the handpiece is correctly calibrated and matches the specified torque range. If using a non-matching handpiece, the actual torque may not display accurately.
Compatibility
Q: Is the Implant Air compatible with my existing dental equipment?
A: Yes, it works with a wide range of E-type handpieces and supports multiple speed ratios for various surgical needs.
Q: Can I use disposable irrigation tubing with the Implant Air?
A: Yes, the device is adaptable to disposable water pipes, ensuring hygiene and preventing cross-contamination.
Is to provide high quality equipments/supplies for all dental professionals.
Mon-Fri: 9 AM - 5 PM
!