Buy Together

Woodpecker TFRK (Terauchi File Removal Kit)

Sale price
$988.55
Regular price
$1,163
You save
15%
Taxes and shipping calculated at checkout
American Express
Apple Pay
Mastercard
PayPal
Shop Pay
Visa
Specifications
Packing List

1. TFRK-Gutta-Percha Removal Hand Instrument (TFRK-GPR)
2. TFRK-Micro Trephine Bur (TFRK-MT)
3. TFRK- Micro Explorer (TFRK-ME)
4. Modified Gates Glidden Drill #3 (MGG #3)
5. Martensitic-phased NiTi Rotary Instrument
6. Broken File Removal Tips ( E87, E88, E89 )
7. TFRK-Loop (TFRK-L:Yoshi Loop)
8. Brownie Polishing Point (TFRK-P)

Warranty

TFRK-Gutta-Percha Removal Hand Instrument (TFRK-GPR)
Made of stainless steel, 4% taper
Can be pre-curved to fit the canal curvature
With delta cones (max. diameter: 0.35mm) on both end 
Used for the removal of filling material remnants and for the removal of necrotic pulp tissues or debris in a narrow space. Smaller size pyramidal tip can make it very easy to scrape gutta-percha root fillings from the canal wall.

TFRK- Micro Explorer (TFRK-ME) 
Made of stainless steel, a sharp 0.1mm-tip-diameter explorer, double ended, 6% taper, smooth-surfaced.The TFRK-ME has extremely fine spear-shaped tips with a smooth surface for bypassing ledged canals and exploring the canal for broken files or other impediments. This instrument can be bent to meet the canal curvature so that the TFRK tips can be precurved the same way as it is before use. When there is a ledge formed coronal to the separated file in the canal, the TFRK-ME can be used to locate the original canal and the ledge can be reduced by using it with several push-pull strokes.

TFRK-Micro Trephine Bur (TFRK-MT)

Inner diameter of the MT is Ф0.5mm whereas the outer diameter of the MT is 0.8 mm.
TRK-MT can be used when the canal curvature is <15°and the coronal diameter of the broken file is 0.45 mm. The inner depth of the MT is 1 mm to expose a 1 mm-portion of the broken file. Spin the MT at 600гр counterclockwise in a short in/out motion to expose the coronal 1 mm-portion of the broken file after the canal enlargement with the MG #3 rotating at 2500 pm to the broken file. If the canal curvature is >15°. a size # 60/.02 taper flexible NiTi rotary file should be used to enlarge the canal to the broken file.

Modified Gates Glidden Drill #3 (MGG #3)
The pilot tip of the Gate Glidden Drill #3 is cut off so that the root canal to the broken file can be enlarged to at least 0.45 mm as the tip diameter of the MGG #3 is 0.45 mm. It is used at 2500 pm clockwise with a brushing motion against the outer wall to create a funnel shape.

Martensitic-phased NiTi Rotary Instrument
K-Endo (K6 N60 2% L25)
60%, 2% taper, NiTi file in the martensitic phase at 37°C
If the coronal diameter of the broken file is >0.45 mm or the canal curvature is >15°, use this rotary instrument to enlarge the canal to the broken file at 500 pm counterclockwise.

Broken File Removal Tips (E87,E88,E89)
TFRK-Katana Vertical (TFRK-Katana V or E88)
TFRK- Katana Horizontal (TFRK-Katana H or E89)
TFRK-Katana V/H is designed with an extremely thin sword -shaped tip to create a 90-degree semicircular ditch on the inner wall of the broken file. They.an be pre-curved to be adapted to the canal curvature. Activate ultrasonic with the flat surface directed to the broken file from the inner wall of the canal. 

TFRK-Straight (TFRK-S or E87)
TFRK-S is characterized by an extremely sharp cone-shaped tip: 0.1 mm diameter tip with 1% taper that can be pre-curved to be adapted to the canal curvature.
• Feature 1: Extend the grooved space to a 180°semicircular ditch until the broken
file is seen dancing after the 90° semicircular space created on the inner wall with the Katana V/H.
• Feature 2: Remove the broken file
• Feature 3: Create a thin space between the canal wall and gutta-percha root fillings
for the introduction of the TFRK-GPR
• Feature 4: Remove necrotic pulp tissues and debris from an isthmus or a thin space

TFRK-Loop (TFRK-L:Yoshi Loop)
Used to retrieve the broken file after loosening it in preparation with ultrasonic when the broken file is longer than 4.5 mm or the broken file did not come out with ultrasonic in 10 seconds at removal attempts. The loop size is adjusted to the diameter of the broken file with an endodontic explorer and bent to 45 degrees to facilitate the placement of the loop over the broken file. The loop cannula is replaceable. The damaged loop can be quickly and easily replaced with a new loop.
There are two sizes of the loop wire: 0. 12 mm and 0.08 mm, suitable for different clinical situations with varying root canal diameters and resistance.
The maximum diameter of the microtube holding the loop is 0.5 mm and it has a 23 mm length. The microtube can be pre-curved to facilitate its placement into the root canal.

Brownie Polishing Point (TFRK-P)
A silicone rubber-based tool used with a straight handpiece. It is designed for sharpening ultrasonic tips to the desired shape and can also be used for polishing to enhance sharpness.

-----------------------------------

Products Sold Separately

Endo File Remover: TFRK-L

  • Intended to be used during dental root canal treatment to remove the broken root canal file.
  • Product Performance: -The external surface of the instrument is smooth and free of burrs. -Passive products -Non-sterile supply.
  • This product  used as disposable .
  • This device is only applicable to its corresponding scope of application, and is not used for other purposes, which will damage the device or have a poor effect.
  • For product installation please view manual included in packaging.
  • Package includes: Casing & 4 needle cores (2* L12, 2*L8)

TFRK Needle Core of Endo File Remover L12 / L8

A structural component of Endo file remover produced by Guilin Woodpecker Medical instrument. It is only used for Endo file remover by Guilin Woodpecker Medical instrument. Each pack comes with 1 needle.

2 sizes available: 0.8 mm & 0.12 mm

Ultrasonic Scaler Tip/ Broken File Removal Tips By Dr. Terauchi

  • This product consists of a head part and tail part. The tail part is connected to the ultrasonic scaler and it is replaceable. It is driven by an Ultrasonic Scaler.
  • Used in conjunction with ultrasonic Scaler; It is suitable for cleaning and shaping of tooth surface, root canal and other parts.
  • Package includes: 1. Ultrasonic Wrench 2. TFRK-S or 87 3.TFRK-KATANA V or 88 4.TFRK- KATANA H or 89 5. Steel tip holder.

E87/ED87 Tip - Jointly Developed with Dr.Yoshi Terauchi

Tip for broken file removal. 0.1mm tip head, extremely thin and conical, used to remove dentin around the broken file.

E88/ED88 Tip - Jointly Developed with Dr.Yoshi Terauchi

Tip for broken file removal. 0.1mm thickness tip head, extremely-thin sword shaped, front and back directed, used to remove dentin around the broken file

E89/ED89 Tip - Jointly Developed with Dr.Yoshi Terauchi

Tip for broken file removal. 0.1mm thickness tip head, extremely-thin sword shaped, left and right directed, used to remove dentin around the broken file. 

1. What is the primary use of the TFRK?

The TFRK is designed to safely remove broken endodontic files from root canals during dental procedures.

2. Can the kit be reused?

Yes, the entire kit comes in an autoclavable cassette, allowing for sterilization and reuse.

3. What types of ultrasonic scaler tips are included in the kit?

The kit includes straight and sword-shaped tips: E87/ED87, E88/ED88, and E89/ED89. These tips are compatible with UDS and DTE ultrasonic scalers.

4. How do I know which tool to use for different root canal curvatures?

For canal curvatures greater than 15°, use the K-ENDO K6 N60 rotary file. For curvatures under 15°, GATE DRILLS #3 or Trephine TFRK-MT may be used based on the file size and canal dimensions.

5. Is there any specific patient caution?

Yes, caution is advised when using the TFRK on patients with heart disease, mental disturbances, or children.

6. Can the loop in the Endo file remover (TFRK-L) be replaced?

Yes, the loop in the Endo file remover is replaceable and can be adjusted to fit the broken file.

7. How should I maintain the sharpness of the tips?

The included polishing rod (TFRK-P) can be used to sharpen the tips of the ultrasonic scaler and dental explorers to maintain their effectiveness.

FAQs on Terauchi File Removal Techniques 

8. What should I use for removing separated files with coronal diameters greater than 0.45 mm or canal curvature greater than 15 degrees?

If the coronal diameter of the separated file is greater than 0.45 mm or the canal curvature exceeds 15 degrees, use the K-ENDO K6 N60 2% L25 file to create a staging preparation to the edge of the separated file.

9. What technique should I use for removing separated files with coronal diameters less than 0.45 mm or canal curvature less than 15 degrees?

For smaller coronal diameters (< 0.45 mm) or less canal curvature, use GATE DRILLS #3 bur to create sufficient working space for the TFRK-MT bur. This helps expose the coronal portion of the file segment while reducing the risk of ledging.

10. How should I operate the TFRK-MT bur for file removal?

The TFRK-MT bur should be used in a counter-clockwise motion at 600 RPM to create an unscrewing effect that can help spin the separated file out of the canal. Avoid exceeding 800 RPM to prevent ledging, especially in curved canals.

11. When and how should I use ultrasonic tips during file removal?

After creating a space with GATE DRILLS #3 and TFRK-MT burs, use TFRK ultrasonic tips to further expose the coronal portion of the separated file. Start with a low power setting, gradually increasing it until resonance is achieved. These tips should not be used at high power, as they are delicate and can break due to fatigue.

12.How can I use ultrasonic tips to loosen a separated file?

Use the E88/ED88, E89/ED89, or E87/ED87 ultrasonic tips to create a semicircular space around the separated file. Apply intermittent pulses of ultrasonic power to loosen the file without causing excessive heat or fatigue to the instrument. Always focus activation on the inner curve of the canal to avoid driving the file further apically.

13. What should I do if the separated file is resistant to ultrasonic activation?

If the separated file does not disengage after 60 seconds of ultrasonic activation, consider cutting more dentin with the E87/ED87 tip along the canal wall adjacent to the file. Deepening the trough can loosen the file. You may also use the Endo file remover (Yoshi Loop) if ultrasonic techniques are unsuccessful.

14. How do I use the Endo file remover to extract a file fragment?

To use the Endo file remover (Yoshi Loop), ensure that the canal is wide enough (at least 0.4 mm). Adjust the loop size to fit the coronal portion of the separated file. Slide the loop over the file, tighten it by pulling back on the plastic button, and then gently pull the loop to dislodge and remove the file.

15. What should I do if the Endo file remover slips off during file extraction?

If the Loop slips off, readjust the loop size using an explorer, reinsert the loop, and try again. It may take several attempts to secure the separated file. Ensure the file has been sufficiently loosened before engaging it with the Loop.

16. How can I prevent further fracturing of the separated file during ultrasonic activation?

Apply ultrasonic activation only to the inner curve of the canal. Creating a thin trough on the inside of the canal curvature reduces the risk of secondary fractures. Avoid activating the ultrasonic tip on the outside curvature, as this may push the file deeper into the canal.

17. What should I do if the separated file fragment doesn’t move after multiple attempts?

If the file is longer than 4.5 mm and ultrasonic activation fails, or if a shorter file doesn’t exit within 10 seconds, switch to using the Endo file remover for more efficient extraction. This tool is especially effective for files shorter than 4.5 mm that resist ultrasonic removal.

FAQs on Cleaning, Disinfection, and Sterilization

18. What are the steps for automated cleaning of the Endo File Remover?

  • Remove the handle, lock nut, and needle core, and rinse with pure or distilled water.
  • Dry with a soft cloth and place in a clean tray.
  • Run the automatic cleaning using a washer-disinfector, following pre-wash, wash, and rinse cycles as specified. Ensure the cleaning agent used is neodisher MediZym and complete the process with 20 minutes of drying.

19. What should I do if my automatic cleaning equipment doesn’t have a drying function?

  • Use a soft absorbent cloth to remove water, or dry the product with compressed air until no liquid is visible. Alternatively, dry the product in a medical drying cabinet at 80°C-120°C for 15-40 minutes.

19. How do I visually inspect the Endo File Remover after cleaning?

Ensure there are no visible stains. If there are, repeat the cleaning process. Check for damage like crushing, corrosion, or bending, and discard the product if it’s damaged.

20. What are the sterilization requirements for the Endo File Remover?

  • Pack the product in EN ISO 11607-compliant material.
  • Use fractionated pre-vacuum steam sterilization at 134°C, 2.0-2.3 bars pressure, for 5 minutes, with 20 minutes of drying time.

21. Can I use alternative sterilization methods like ethylene oxide or radiation?

No, alternative methods like ethylene oxide, formaldehyde, and low-temperature plasma sterilization are not recommended. The manufacturer assumes no responsibility for non-recommended methods.

22. How long can I store the sterilized Endo File Remover?

Sterilized products should be stored in a sealed bag or container for up to 7 days. If exceeded, reprocess the product before use.

23. What is the automated cleaning process for a Dental Explorer?

Rinse with pure or distilled water, dry with a soft cloth, and place in a washer-disinfector. Follow the washer program with pre-washing, cleaning with neodisher MediZym, rinsing, and drying for 20 minutes.

24. Is disinfection necessary for the Endo File Remover or Dental Explorer?

No, disinfection is not required because these products must be sterilized after cleaning.

25. What should I check after sterilization of dental instruments?

Check the packaging for damage. If damaged, re-clean and sterilize before use. Ensure the storage environment is clean and disinfected regularly.

26. What is the sterilization procedure for the tips of an Ultrasonic Scaler?

The scaler tips should be cleaned and disinfected using washer-disinfectors and then sterilized up to 300 times. Avoid exposure to temperatures above 138°C, as this can damage the product.

27. How should I store sterilized instruments?

Store them in a clean, dry, ventilated area with controlled humidity (10-93%) and temperature (-20°C to +55°C). Ensure the storage time does not exceed 7 days before reprocessing.

28. Can I use strong detergents to clean dental instruments?

No, strong detergents with pH levels higher than 9 or lower than 5 can reduce the lifespan of the products. Always use the recommended cleaning agents.

Frequently bought together

Woodpecker TFRK (Terauchi File Removal Kit)
Woodpecker TFRK (Terauchi File Removal Kit)
This item: Woodpecker TFRK (Terauchi File Removal Kit)
Price
$988.55
Woodpecker / DTE 812 MT - Endo Motor
Woodpecker / DTE 812 MT - Endo Motor
Woodpecker / DTE 812 MT - Endo Motor
Price
$2,599
Woodpecker / DTE Ultrasonic Scaler D600 -LED
Woodpecker /  DTE Ultrasonic Scaler D600 -LED
Woodpecker / DTE Ultrasonic Scaler D600 -LED
Price
$890.10
DTE Terauchi Single Tips E87/E88/E89
DTE Terauchi Single Tips E87/E88/E89
DTE Terauchi Single Tips E87/E88/E89

Terauchi Single Tip E87 / ED87

Price
$42.99
Woodpecker / Terauchi TFRK Needle Core of Endo File Remover L8 / L12
Woodpecker / Terauchi TFRK Needle Core of Endo File Remover L8 / L12
Woodpecker / Terauchi TFRK Needle Core of Endo File Remover L8 / L12

Terauchi TFRK Needle Core of Endo File Remover L8

Price
$67
Total price: $4,587.64