1. Is the Woodpecker / DTE D600 Dental Scaler approved by Health Canada?
Yes, the Woodpecker / DTE D600 Dental Scaler is approved by Health Canada, ensuring it meets all safety and quality standards.
2. How long is the warranty for the Woodpecker / DTE D600 Dental Scaler?
Main Unit: 1 Year / Handpiece: 1 Year / Accessory Parts: 6 Months, and consumables are not covered.
Cleaning, Disinfection, and Sterilization
3. How should the Woodpecker / DTE D600 Ultrasonic Dental Scaler be cleaned after use?
The scaler should be flushed under irrigation mode for 20-30 seconds, then removed, and rinsed with pure, distilled, or deionized water. It should be dried with a clean, soft cloth and placed in a clean tray.
4. Can strong detergents or disinfectants be used on the Woodpecker / DTE D600 Ultrasonic Dental Scaler?
No, strong detergents and disinfectants with a pH greater than 9 or less than 5 can reduce the lifespan of the scaler. The manufacturer is not responsible for any damage caused by such products.
5. What is the maximum number of sterilization cycles for the Woodpecker / DTE D600 Ultrasonic Dental Scaler, tips, and wrench?
The handpiece can undergo 600 sterilization cycles, the tips 300 cycles, and the wrench 1000 cycles.
6. How can I clean the water pipe and maintain the Woodpecker / DTE D600 Ultrasonic Dental Scaler to prevent bacteria buildup?
Use the "Cleaning Mode" to wash and disinfect the water pipe. Fill the tank with distilled water or a mineral solution, activate the cleaning mode, and allow the scaler to self-clean for 30 seconds. This process helps reduce crystal buildup and bacteria in the water pipe.
Usage Precautions
7. What should be done if the Woodpecker / DTE D600 Ultrasonic Dental Scaler tip is damaged or worn?
If the tip is damaged or excessively worn, it should be replaced immediately. Using a damaged tip can affect performance and patient safety.
8. Why is it important to ensure smooth water flow during the operation of the Woodpecker / DTE D600 Ultrasonic Dental Scaler?
Smooth water flow is essential to prevent the scaling tip from overheating, which could cause injury to the patient's tooth surface.
9. Can the Woodpecker / DTE D600 Ultrasonic Dental Scaler be used with impure water sources?
No, impure water sources should not be used. Only pure, distilled, or deionized water should be used to ensure proper operation and avoid damage to the scaler.
10. Can I use tap water or a water tank with solutions for the Woodpecker / DTE D600 Ultrasonic Dental Scaler?
Yes, you can use tap water or a water tank with solutions. However, it is recommended to use distilled water or a clean water source to ensure the best performance and longevity of the equipment.
11. What types of solutions can be used in the water tank of the Woodpecker / DTE D600 Ultrasonic Dental Scaler?
You can use various dental solutions in the water tank, such as chlorhexidine, hydrogen peroxide, or sterile saline, depending on the clinical requirements. Always ensure the solution is compatible with the scaler's water system.
12. How do I properly install and set up the Woodpecker D600 Ultrasonic Dental Scaler?
Start by checking that all components are present according to the packing list. Place the main unit on a stable surface, connect the foot switch, attach the water pipe to a clean water source, and choose the appropriate scaling tip. Once everything is connected, turn on the power and adjust settings on the touch panel.
13. What should I do if the scaling tip doesn’t vibrate but water flows out when I step on the foot switch?
If this occurs, ensure that the scaling tip is screwed tightly onto the handpiece. If the tip is properly secured and the issue persists, there may be a loose connection between the handpiece and the circuit board, or the handpiece might need repair.
Maintenance and Storage
14. How should the Woodpecker / DTE D600 Ultrasonic Dental Scaler be stored when not in use?
The scaler should be stored in a clean, dry, and ventilated environment with a relative humidity of 10% to 93% and a temperature range of -20°C to +55°C. After sterilization, it should be stored in a medical sterilization bag or a clean sealing container.
15. What precautions should be taken during the transportation of the Woodpecker / DTE D600 Ultrasonic Dental Scaler?
During transportation, the scaler should be protected from excessive shock and vibration, kept away from dangerous goods, and shielded from exposure to sunlight, rain, or snow.
16. Who should avoid using the Woodpecker / DTE D600 Ultrasonic Dental Scaler?
The scaler should not be used on patients with hemophilia or those with heart pacemakers. Patients with heart disease, pregnant women, and children should use the scaler with caution.
17. Can the Woodpecker / DTE D600 Ultrasonic Dental Scaler be used by a professional technician not authorized by the manufacturer?
No, only maintenance, repair, or modifications performed by the manufacturer or an authorized dealer are covered under warranty. Unauthorized modifications could lead to irretrievable damage.