The Woodpecker Contra Angle CA161 is designed for precision in endodontic treatments, specifically crafted to hold and drive rotary instruments with an adjustable speed range of 100-1,200 rpm. This flexibility allows for greater control and efficiency during rotary processing. Its smooth transmission, combined with low vibration and noise, enhances both operator comfort and procedural accuracy. Built for longevity, the CA161 offers a durable solution with high cutting efficiency, making it an excellent choice for dental professionals.
Key Features:
Adjustable speed range from 100 to 1,200 rpm for enhanced control
Smooth transmission with low vibration and noise
High cutting efficiency for improved performance
Durable design for long-lasting reliability
Models:
CA161
Transmission and Gear Ratio:
Gear Ratio: 6:1
Output Speed Range:
CA161: 100-1200 rpm
Output Torque Range:
CA161: 0.4-5.0 Ncm
Compatibility
Woodpecker 812 MT: Endo Motor and Apex Locator with Sonic Vibration
Woodpecker Smart A: Endo Motor
Woodpecker Ai-Motor (T-mode): Designed by Dr. Yoshi Terauchi
Woodpecker Ai-Motor: 1st Brushless Endo Motor by Woodpecker
Woodpecker Endo Radar Pro: Endo Motor
Woodpecker Endo Radar: Wireless Endo Motor Covers Apex Locator
Woodpecker Endo Radar Plus: Full Touch Button Design
Woodpecker Endo Smart+: Brushless Endo Motor
Woodpecker Endo Radar Pro ARI
Woodpecker MotoPex: High-Performance Brushless Motor
Woodpecker Endo Smart Pro: Brushless Endo Motor
Chuck Type:
Push-button for quick and easy file changes.
Rotation Modes:
Continuous forward, continuous reverse, and reciprocating rotation
File Shank Attachment:
Diameter: 2.35mm (ISO1797-1 Type 1).
Minimum Shank Length: 11mm.
Maximum Overall Length of Rotary Instrument: 46mm.
Environmental Operating Conditions:
Temperature: 10°C - 40°C.
Relative Humidity: 30% - 75%.
Atmospheric Pressure: 70kPa - 106kPa.
Material and Durability:
Designed to withstand 600 cycles of sterilization without degradation of performance.
Cleaning and Sterilization:
Not suitable for ultrasonic cleaning.
Can be sterilized using a fractionated pre-vacuum steam sterilization process with a minimum requirement of 4 minutes at 132°C/134°C.
Maximum sterilization temperature: 137°C.
Requires regular lubrication, particularly after each use or every 60 minutes of continuous use.
Safety Warnings:
Not suitable for use by patients with hemophilia, pacemakers, or those with severe systemic infections.
Not recommended for use by pregnant women or those with mental disorders.
Storage Conditions:
Storage Temperature: -20°C to +55°C.
Relative Humidity: 10% to 93%.
Should be stored in a dry, clean environment away from harmful chemicals.
After-Sales Service:
Woodpecker offers maintenance during the warranty period, with service managed by professionals. Please contact seller.
What is the CA161 Contra Angle used for?
The CA161 is designed for holding and driving rotary instruments in endodontic treatments. It supports continuous and reciprocating rotations for precise dental procedures.
What are the speed and torque ranges for the CA161?
The CA161 operates within a speed range of 100–1,200 RPM and a torque range of 0.4–5.0 Ncm.
What is the gear ratio of the CA161?
The gear ratio for the CA161 is 6:1.
What types of instruments are compatible with the CA161?
The CA161 is compatible with ISO 1797-1 Type 1 rotary instruments with a diameter of 2.35 mm and a maximum length of 46 mm.
What are the main features of the CA161?
The CA161 features smooth transmission, low vibration, low noise, high cutting efficiency, and a long service life.
How do I connect and disconnect the CA161 to a motor handpiece?
To connect, align the positioning pins of the contra angle with the motor handpiece slots and insert until it clicks. To disconnect, pull the device straight out after the motor is fully stopped.
What precautions should I take while using the CA161?
Avoid pressing the push-button during operation to prevent overheating or file ejection.
Ensure shanks/files are securely locked to prevent accidents.
Do not use non-recommended shanks/files to avoid malfunctions.
Is the CA161 autoclavable?
Yes, the CA161 can withstand up to 600 cycles of sterilization using a fractionated pre-vacuum steam sterilization process with a maximum temperature of 137°C.
How should I clean and maintain the CA161?
Clean the device immediately after use with cold water (<40°C), pre-clean manually, and follow either automated or manual cleaning methods. Regular lubrication is required after each use or every 60 minutes of continuous operation.
What are the recommended storage conditions for the CA161?
Store the CA161 in a dry, clean, and dust-free environment with temperatures ranging from -20°C to 55°C and relative humidity between 10% and 93%.
Who can use the CA161?
The CA161 is intended for use by qualified dental professionals in hospitals, clinics, or dental offices.
What is the structure of the CA161?
The CA161 comprises a handle, driving medium, and head for optimal functionality in clinical settings.