Please be aware this is pre order
The products will be shipped to you once they become available
1. Main unit x 1
2. Touch Probe x 1
3. File clip x 2
4. Lip hook x 5
5. Probing x 2
6. Adapter x 1
7. Tester x 1
8. Battery x 1
9. Instruction manual x 1
10. Qualified certificate x 1
11. Warranty card x
I)Period validity:
We offer two years free repair on main unit and six months on spare parts from the date of purchase, warranty card must be attached.
II) Range of warranty:
Within the warranty period of validity, we are responsible for any troubles caused by quality problems or products technique and structure.
III) The following are beyond our warranty:
The Fifth Generation Apex Locator
Here are some videos for your viewing!
1. What are the main features of the DPEX V Apex Locator?
2. How do I prepare the DPEX V Apex Locator for measurement?
3. How do I test the DPEX V Apex Locator with a tester?
4. How do I determine the working length using the DPEX V Apex Locator?
5. Can the DPEX V be connected to an Endo Motor?
6. How do I charge the DPEX V?
7. What should I do if the length measurement is inaccurate?
8. Are there any conditions that may affect the measurement accuracy?
Cleaning, Disinfection, and Sterilization FAQs:
1. What type of cleaning agents should I avoid to prevent damaging the device?
Avoid using strong detergents and disinfectants with a pH greater than 9 (alkaline) or less than 5 (acidic), as they can reduce the product's lifespan. The manufacturer will not be responsible for damage caused by such chemicals.
2. How many times can I sterilize the lip hook, file clip, and touch probe?
3. What are the steps for cleaning after use?
4. Can I use ultrasonic cleaning?
No, ultrasonic cleaning is not recommended for these products.
5. How do I perform automated cleaning?
Use a washer-disinfector certified according to EN ISO 15883, ensuring it has a flushing connector for internal cavities. Cleaning agents such as pure water, distilled water, deionized water, or multi-enzyme solutions can be used.
6. What is the recommended disinfection procedure?
Automated disinfection is preferred, using a washer-disinfector certified according to EN ISO 15883. The disinfection temperature should not exceed 134°C, and the process should last no more than 20 minutes.
7. How should the device be dried after cleaning?
You can use either compressed air (max 3 bar pressure) or a medical drying cabinet at 80°C to 120°C for 15–40 minutes. Ensure drying is done in a clean environment.
8. What should I do if there are still visible stains after cleaning?
If stains remain, repeat the entire cleaning and disinfection process. Do not proceed with sterilization until the product is visibly clean.
9. What are the recommended sterilization procedures?
Only use steam sterilization via the fractional pre-vacuum procedure. The highest sterilization temperature should be 138°C, with at least 4 minutes at 132°C to 134°C and a pressure of 2.0 to 2.3 bars.
10. Can I store the sterilized device indefinitely?
No, after sterilization, the product should be stored in a medical sterilization bag in a special storage cabinet. The storage time should not exceed 7 days. If exceeded, reprocess before use.
11. What precautions should I take during transportation?
Prevent excessive shock and vibration, avoid exposure to the sun, and ensure it is not mixed with dangerous goods during transportation.