FI-G:
Classification:Class Ⅱ(AC/DC power adapter)
Available temperatures:150℃→180℃→200℃→230℃
Time consumption for charging:About 2.5h
Duration after full charging:If each operation lasts for 5s,it can work for 1500 times
Power supply:Input: AC100V-240V
50/60Hz 800mA Output: DC15V/1.6A
Battery capacity:2000mAh
Size:23.8mm×158.3mm×23.8mm(Fi-P)
75.5mm×149.7mm×62.6mm(Charging base)
Weight:80g(Fi-P) 195g(Charging base)
167g(Power adapter)
0.5mm injection needle
15 seconds fast heating
360 degree rotatable injection needle
Pushing ram with anti-return structure
FI-P:
Classification:Class Ⅱ(AC/DC power adapter)
Available temperatures:150℃→180℃→200℃→230℃
Time consumption for charging:About 2.5h
Duration after full charging:If each operation lasts for 5s,it can work for 1500 times
Power supply:
Input:AC100V-240V 50/60Hz 800mA
Output: DC15V/1.6A
Battery capacity:2000mAh
Size:23.8mm×158.3mm×23.8mm(Fi-P)
75.5mm×149.7mm×62.6mm(Charging base)
Weight:80g(Fi-P) 195g(Charging base)
167g(Power adapter)
0.2 second fast heating
0.35mm pre-bend tip
FI-P
1. Main unit x 1
2. Charging stand x 1
3. Power adapter x 1
4. WP4004 tip (Taper 4%) x 1
5. WP4504 tip (Taper 4%) x 1
6. WP5506 tip (Taper 6%) x 1
7. WP5508 tip (Taper 8%) x 1
8. Heat insulation sleeve of tips x 4
9. Instruction manual x 1
10. Qualified certificate 1
11. Packing list x 1
FI-G
1. Main Unit x 1
2. Charging stand x 1
3. Power adapter x 1
4. Power adapter with cable x 1
5. Gutta-percha injection needle 23G#24mm x 1
6. Gutta-percha injection needle 23G #28mm x 1
7. Gutta-percha injection needles 25G #24mm x 2
8. Heat insulation sleeve of needle x 1
9. Heat insulation hood x 2
10. Pushing ram x 1
11. Cleaning brush x 2
12. Wrench x 1
13. Instruction Manual x 1
14. Qualified certificate 1
15. Packing list x 1
Period validity:
Main Unit: 1 Year / Accessory Parts: 6 Months / Consumables: No Warranty
Range of warranty:
The following are beyond our warranty:
Fi-P & Fi-G
The Fi-P (Heat & Packing) and Fi-G (Hot Melting & Filing Gun) work in conjunction with each other for the ultimate gutta-percha obturation system for your root canal procedures.
Fi-G enables the shortest heating and melting time within 15s
Specially formulated Gutta Percha bar with excellent flowing characteristics designed to be used with Fi-G.
Extra/different tips each sold separately
Fi-P adopts wireless, horizontal type, temperature adjusting, and left or right hand operation design, endowing it with outstanding function and characteristics.
Here are some videos for your viewing. Enjoy!
Fi-P
1. What temperature settings are available on the Fi-P device?
The device has four preset temperature settings: 150°C, 180°C, 200°C, and 230°C. You can cycle through these by pressing the "ON/OFF" button when the device is turned on.
2. How do I heat the Work Tip?
Once the device is on and the Work Tip is connected, press the Heating button to start heating. Release the button to stop heating. If you press and hold the Heating button for more than 10 seconds, the device will stop heating. To resume, release and press the button again.
3. How can I check the battery level?
The battery level is displayed on the screen in real-time. When fully charged, five grids are displayed. If only one grid is displayed or the screen shows a space, the battery is low and needs to be charged immediately.
4. What should I do if the device doesn't heat up or shows an error code?
Ensure the Work Tip is properly installed. If the connection is poor or the Work Tip isn't installed, an error code will appear on the display screen. Reinstall the Work Tip or check the connection.
5. How long does it take to fully charge the Fi-P device?
It takes approximately 2.5 hours to fully charge the device. Ensure the device is fully charged before use. The charging indicator on the base will show yellow while charging and green when fully charged.
6. How do I replace the Work Tip?
Turn off the device before replacing the Work Tip to avoid accidental burns. Pull off the old Work Tip, select a new one, and install it by inserting it into the instrument at the appropriate angle. Always install the Work Tip Protector to prevent patient burns during operation.
7. How should I clean and sterilize the Work Tip after use?
After each use, immediately clean the Work Tip with a soft cloth to remove gutta-percha residue. Disinfect and sterilize the tip according to the guidelines provided in the manual. Avoid using strong detergents or exposing the device to temperatures above 138°C.
8. What should I do if the battery is not charging properly?
Ensure that the device is correctly placed on the charging base and that all connections are secure. If the LED on the base is flashing or not lit, recheck the connections or try another power outlet.
9. How do I maintain the device for long-term use?
Charge the device regularly, even if it's not in use, to protect the battery. Avoid letting the battery completely discharge. Clean, disinfect, and sterilize the device and its components according to the recommended procedures to ensure longevity.
Fi-G
10. How do I turn on the Woodpecker Fi-G Obturation System?
To turn on the device, press and hold the "ON/OFF" button on either side of the instrument. The display screens on both sides will light up, indicating that the device is powered on. If there is no operation for 10 minutes, the device will automatically shut down.
11. How do I adjust the temperature for heating gutta-percha?
After turning on the device, press the "ON/OFF" button again to cycle through the preset temperatures (150°C, 180°C, 200°C, 230°C). The display will show the selected temperature. Choose the appropriate temperature based on the size of the Gutta Percha Injecting Needle you are using.
12. What should I do if the battery level is low?
When the battery level indicator shows one grid or no power, it’s time to recharge the device. Place the instrument on the charging base connected to a power adapter. The LED indicator on the base will show yellow while charging and green when fully charged. It takes approximately 2.5 hours to fully charge the device.
13. How do I load the gutta-percha into the Fi-G Obturation System?
First, ensure the pushing ram is retracted by holding down the limit switch. Tilt the device downwards and insert a single gutta-percha stick into the loading slot. Push the gutta-percha into the heating chamber until fully inserted, indicated by the black marker on the pushing ram being fully advanced.
14. How do I safely replace the Gutta Percha Injecting Needle?
Turn off the device and allow it to cool for at least 5 minutes before replacing the needle. Use the provided wrench to remove the old needle by turning it counterclockwise. Install the new needle by tightening it clockwise, but avoid over-tightening. Use the wrench to bend the needle to the desired angle.
15. How do I clean and maintain the Fi-G Obturation System after use?
After each operation, set the temperature to 150°C to soften any remaining gutta-percha, then use the cleaning brush to remove residual material from the heating chamber. Make sure to clean, disinfect, and sterilize the Thermal Protector Cap, Gutta Percha Injecting Needle, and other accessories according to the manual.
16. What should I do if the charging indicator flashes or does not light up?
If the LED on the charging base is flashing or not lighting up, check all connections and ensure the power adapter is properly connected to the charging base and a standard socket. If the issue persists, consider inspecting the charging base or contacting customer support for further assistance.
Is to provide high quality equipments/supplies for all dental professionals.
!